CAN/CSA-CEI/IEC 61000-4-9:22 PDF

CAN/CSA-CEI/IEC 61000-4-9:22 PDF

Name:
CAN/CSA-CEI/IEC 61000-4-9:22 PDF

Published Date:
08/05/2022

Status:
Active

Description:

Electromagnetic compatibility (EMC) - Part 4-9: Testing and measurement techniques - Impulse magnetic field immunity test

Publisher:
Canada National Standard/Canadian Standards - CEI/IEC

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$90.3
Need Help?

CSA Preface 

This is the second edition of CSA IEC 61000-4-9, Electromagnetic Compatibility (EMC) — Part 4-9: Testing and measurement techniques — Impulse magnetic field immunity test, which is an adoption without modification of the identically titled IEC (International Electrotechnical Commission) Standard 61000-4-9 (second edition, 2016-07). It supersedes the previous edition, published in 2002 as CAN/CSA-IEC 61000-4-9 (adopted IEC 61000-4-9:1993+A1:2000). For brevity, this Standard will be referred to as "CSA IEC 61000-4-9" throughout. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was reviewed for Canadian adoption by the CSA Subcommittee on Electromagnetic Compatibility Measurement Methods and Basic Standards for High Frequencies, under the jurisdiction of the CSA Technical Committee on Electromagnetic Compatibility and the CSA Strategic Steering Committee on Power Engineering and Electromagnetic Compatibility, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope and object This part of IEC 61000 specifies the immunity requirements, test methods, and range of recommended test levels for equipment subjected to impulse magnetic disturbances mainly encountered in: – industrial installations, – power plants, – railway installations, – medium voltage and high voltage sub-stations. The applicability of this standard to equipment installed in different locations is determined by the presence of the phenomenon, as specified in Clause 4. This standard does not consider disturbances due to capacitive or inductive coupling in cables or other parts of the field installation. Other IEC standards dealing with conducted disturbances cover these aspects. The object of this standard is to establish a common reference for evaluating the immunity of electrical and electronic equipment when subjected to impulse magnetic fields. The test method documented in this part of IEC 61000 describes a consistent method to assess the immunity of an equipment or system against a defined phenomenon. 

NOTE As described in IEC Guide 107, this is a basic EMC publication for use by product committees of the IEC. As also stated in Guide 107, the IEC product committees are responsible for determining whether this immunity test standard is applied or not, and if applied, they are responsible for determining the appropriate test levels and performance criteria. TC 77 and its sub-committees are prepared to co-operate with product committees in the evaluation of the value of particular immunity test levels for their products. This standard defines: – a range of test levels; – test equipment; – test setups; – test procedures. The task of the described laboratory test is to find the reaction of the equipment under test (EUT) under specified operational conditions to impulse magnetic fields caused by switching and lightning effects. 


Edition : 2nd
File Size : 1 file , 4.7 MB
ISBN(s) : 9781488345647
Number of Pages : 83
Product Code(s) : 2430392, 2430392
Published : 08/05/2022

History

CAN/CSA-CEI/IEC 61000-4-9:22
Published Date: 08/05/2022
Electromagnetic compatibility (EMC) - Part 4-9: Testing and measurement techniques - Impulse magnetic field immunity test
$90.3
CAN/CSA-CEI/IEC 61000-4-9:02 (R2020)
Published Date: 07/01/2002
Electromagnetic Compatibility (EMC) - Part 4-9: Testing and Measurement Techniques - Pulse Magnetic Field Immunity Test (Adopted CEI/IEC 61000-4-9:1993 + A1:2000, edition 1.1, 2001-03)
$37.8

Related products

CAN/CSA-CEI/IEC 1000-2-1-97 (R2023)
Published Date: 01/18/2000
Electromagnetic Compatibility (EMC) - Part 2: Environment - Section 1: Description of the Environment - Electromagnetic Environment for Low-Frequency Conducted Disturbances and Signalling in Public Power Supply Systems (Adopted CEI/IEC 1000- 2-1:1990) / Compatibilite electromagnetique (CEM) - Partie
$36.3

Best-Selling Products

NETA ATS-2009
Published Date: 02/19/2009
Standard for Acceptance Testing Specifications for Electrical Power Equipment and Systems, 2009 Edition
$247.5
NETA ATS-2013
Published Date: 2013
Standard for Acceptance Testing Specifications for Electrical Power Equipment and Systems, 2013 Edition
$82.5
NETA ATS-2017
Published Date: 2017
Standard for Acceptance Testing Specifications for Electrical Power Equipment and Systems, 2017 Edition (Errata Included)
$87
NETA ATS-2021
Published Date: 09/18/2020
Standard for Acceptance Testing Specifications for Electrical Power Equipment and Systems, 2021 Edition
$87
NETA ECS-2020
Published Date: 2020
Standard for Electrical Commissioning Specifications for Electrical Power Equipment and Systems, 2020 Edition
$57
NETA ECS-2024
Published Date: 2024
Standard for Electrical Commissioning Specifications for Electrical Power Equipment & Systems, 2024 Edition
$62.7